Filter products

EXTERIOR window tape, white, full-flush SK, 25m
EXTERIOR window connection tape, white, full-flush, SK, 25mSK, 25mEXTERIOR window connection tape, white, full-flushSK,25m. SK, 25m consists of a plasterable fleece composite with 1 SK strip, optionally laminated with butyl strips on one side or alternating sides. The external connection foil is used for fast and secure external sealing of window connection joints that is impermeable to driving rain and open to diffusion, and is used as an external seal that can be plastered over. Installation instructions EXTERIOR window connection tape, white, full-fl. SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (such as for new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Pay attention to the material compatibility. In the case of highly absorbent, sandy substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).

EXTERIOR window tape, white, full-flush SK, 25m
EXTERIOR window connection tape, white, full-flush, SK, 25mSK, 25mEXTERIOR window connection tape, white, full-flushSK,25m. SK, 25m consists of a plasterable fleece composite with 1 SK strip, optionally laminated with butyl strips on one side or alternating sides. The external connection foil is used for fast and secure external sealing of window connection joints that is impermeable to driving rain and open to diffusion, and is used as an external seal that can be plastered over. Installation instructions EXTERIOR window connection tape, white, full-fl. SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (such as for new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Pay attention to the material compatibility. In the case of highly absorbent, sandy substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).

EXTERIOR window tape, white, full-flush SK, 25m
EXTERIOR window connection tape, white, full-flush, SK, 25mSK, 25mEXTERIOR window connection tape, white, full-flushSK,25m. SK, 25m consists of a plasterable fleece composite with 1 SK strip, optionally laminated with butyl strips on one side or alternating sides. The external connection foil is used for fast and secure external sealing of window connection joints that is impermeable to driving rain and open to diffusion, and is used as an external seal that can be plastered over. Installation instructions EXTERIOR window connection tape, white, full-fl. SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (such as for new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Pay attention to the material compatibility. In the case of highly absorbent, sandy substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).

INSIDE window connection tape, red 1 SK, 25m
Window connection tape INSIDE, red 1 SK, 25mWindow connection tape inside consists of a non-woven composite that can be plastered over with 1 SK strip, optionally laminated with butyl strips on one side or alternating sides. The interior connection tape is used for fast and secure interior, airtight and vapour-retardant sealing of window connection joints and can also be used as an interior seal that can be plastered over. On highly porous substrates, we recommend using a butyl & bitumen primer when bonding with butyl. Installation instructions INSIDE window connection tape, red 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (such as for new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Pay attention to the material compatibility. In the case of highly absorbent, sandy substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).
Content: 25 m (€0.85 / 1 m)

INSIDE window connection tape, red 1 SK, 25m
Window connection tape INSIDE, red 1 SK, 25mWindow connection tape inside consists of a non-woven composite that can be plastered over with 1 SK strip, optionally laminated with butyl strips on one side or alternating sides. The interior connection tape is used for fast and secure interior, airtight and vapour-retardant sealing of window connection joints and can also be used as an interior seal that can be plastered over. On highly porous substrates, we recommend using a butyl & bitumen primer when bonding with butyl. Installation instructions INSIDE window connection tape, red 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (such as for new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Pay attention to the material compatibility. In the case of highly absorbent, sandy substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).
Content: 25 m (€1.04 / 1 m)

INSIDE window connection tape, red 1 SK, 25m
Window connection tape INSIDE, red 1 SK, 25mWindow connection tape inside consists of a non-woven composite that can be plastered over with 1 SK strip, optionally laminated with butyl strips on one side or alternating sides. The interior connection tape is used for fast and secure interior, airtight and vapour-retardant sealing of window connection joints and can also be used as an interior seal that can be plastered over. On highly porous substrates, we recommend using a butyl & bitumen primer when bonding with butyl. Installation instructions INSIDE window connection tape, red 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (such as for new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Pay attention to the material compatibility. In the case of highly absorbent, sandy substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).
Content: 25 m (€1.28 / 1 m)

INSIDE window connection tape, red 1 SK, 25m
Window connection tape INSIDE, red 1 SK, 25mWindow connection tape inside consists of a non-woven composite that can be plastered over with 1 SK strip, optionally laminated with butyl strips on one side or alternating sides. The interior connection tape is used for fast and secure interior, airtight and vapour-retardant sealing of window connection joints and can also be used as an interior seal that can be plastered over. On highly porous substrates, we recommend using a butyl & bitumen primer when bonding with butyl. Installation instructions INSIDE window connection tape, red 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (such as for new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Pay attention to the material compatibility. In the case of highly absorbent, sandy substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).
Content: 25 m (€0.74 / 1 m)

VARIO window tape, white, 1 SK, 25m
Window tape VARIO, white, 1 SK, 25mWindow tape VARIO, white, 1 SK, 25m is used to seal the window connection joint. Due to the variable Sd value, this film can be used both indoors and outdoors. Areas of application: Window and door sealing indoors and outdoors. Installation instructions Window tape VARIO, white, 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (e.g. in the case of new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Ensure that the material is compatible. In the case of highly absorbent, sanding substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).

VARIO window tape, white, 1 SK, 25m
Window tape VARIO, white, 1 SK, 25mWindow tape VARIO, white, 1 SK, 25m is used to seal the window connection joint. Due to the variable Sd value, this film can be used both indoors and outdoors. Areas of application: Window and door sealing indoors and outdoors. Installation instructions Window tape VARIO, white, 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (e.g. in the case of new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Ensure that the material is compatible. In the case of highly absorbent, sanding substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).

VARIO window tape, white, 1 SK, 25m
Window tape VARIO, white, 1 SK, 25mWindow tape VARIO, white, 1 SK, 25m is used to seal the window connection joint. Due to the variable Sd value, this film can be used both indoors and outdoors. Areas of application: Window and door sealing indoors and outdoors. Installation instructions Window tape VARIO, white, 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (e.g. in the case of new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Ensure that the material is compatible. In the case of highly absorbent, sanding substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).

VARIO window tape, white, 1 SK, 25m
Window tape VARIO, white, 1 SK, 25mWindow tape VARIO, white, 1 SK, 25m is used to seal the window connection joint. Due to the variable Sd value, this film can be used both indoors and outdoors. Areas of application: Window and door sealing indoors and outdoors. Installation instructions Window tape VARIO, white, 1 SK, 25m All profile openings, e.g. cut edges of extensions and window sill profiles or continuous grooves in fitted roller shutter boxes, must be sealed with sealant. The surfaces to be bonded to the window frame and masonry must be clean and dry, free of dust, grease and release agents (e.g. in the case of new plastic profiles). The surface coating on wooden windows should be a few days old, as the solvents that otherwise escape can reduce the adhesion of the tape. If necessary, remove soiling with grease-dissolving cleaning agents. Ensure that the material is compatible. In the case of highly absorbent, sanding substrates, pre-treat the building structure with an adhesion promoter, e.g. DRG spray primer, DRG spray adhesive or solvent-free primer. In the event of break-outs in the masonry, a clean smooth coat must be applied again. When bonding, the tapes must be applied to the frame without creases, in parallel and pressed down all the way. Allow the tapes to overlap at the corners and seal them so that they are watertight against driving rain. bond airtight. Movement absorption must be ensured by creating sufficient loops in the area of the connection joint. Minimum adhesive width on the window 15 mm, on the wall at least 30 mm The sealing tape must be sufficiently bonded to the masonry in the area of the subsequent plaster cover (rule of thumb: at least 75 % of the contact surface).

Window tape FAB 1500, blue, 1500 1 SK 25 m
The window connection tape FAB 1500, blue, 1 SK 25 m is the water vapour impermeable bridging of the joint between window, door and masonry. It is also used in metal and conservatory construction. The adhesive technology allows a high degree of flexibility when processing the sealing tape. Products with an SD value of >1500 m are defined as impermeable, products with an SD value <0.5 m are considered permeable. Products in the intermediate area are defined as diffusion.
Content: 25 m (€0.80 / 1 m)

Window connection tape for inside, outside and vario
The DE & BG DiCHT interior window tapeconsists of a fully self-adhesive fleece composite with 1 SK strip that can be plastered over .

